一种Stacking集成结构的台风灾害下停电空间预测方法
CSTR:
作者:
作者单位:

(1.武汉理工大学自动化学院,湖北 武汉 430070;2.广东电网有限责任公司,广东 广州 510080; 3.广东电网有限公司电力科学研究院,广东 广州 510080)

作者简介:

侯 慧(1981—),女,博士,副教授,博士生导师,研究方向为电力系统风险评估、能源互联网、电动汽车与电网互动等;E-mail: houhui@whut.edu.cn 陈 希(1997—),男,通信作者,硕士研究生,研究方向为电力系统风险评估。E-mail: 1763854410@qq.com

通讯作者:

中图分类号:

基金项目:

教育部产学合作协同育人项目资助(201902056044);中国南方电网有限责任公司科技项目资助(GDKJXM20198441(036100KK52190053))


A space prediction method for power outage in a typhoon disaster based on a Stacking integrated structure
Author:
Affiliation:

(1. School of Automation, Wuhan University of Technology, Wuhan 430070, China; 2. Guangdong Power Grid Co., Ltd., Guangzhou 510080, China; 3. Electric Power Research Institute of Guangdong Power Grid Co., Ltd., Guangzhou 510080, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为提高电网公司防灾减灾能力,考虑电网、气象、地理等因素,从统计学习的角度提出一种台风灾害下停电空间预测方法。首先,以1 km×1 km网格为单位收集数据,并进行标准化、分类变量独热编码处理与筛选、构造特征等处理后作为模型输入数据。其次,选取随机森林、梯度提升决策树、自适应提升、K最近邻、支持向量机、极限树、决策树以及XGBoost等算法,利用Stacking集成技术构造停电空间预测模型。最后,以广东省某县为研究对象,对模型的停电空间预测性能进行验证。在台风“彩虹”下的预测准确率为0.777 6,召回率为0.914 0。结果验证了在台风灾害下该模型对停电空间预测的可行性与有效性。

    Abstract:

    To improve disaster prevention and the mitigation ability of power grid companies, taking into account the power grid, meteorology and geography, a power outage spatial prediction method in the case of typhoon disasters is proposed from the perspective of statistical learning. First, data are collected in a 1 km×1 km grid, and standardized, classified with variable one-hot encoding and screening, and construction features are processed as input data for the model. Secondly, algorithms such as random forest, gradient boosting decision tree, adaptive boosting, K-nearest neighbor, support vector machine, extreme tree, decision tree, and XGBoost are selected to construct an outage space prediction model using Stacking integration technology. Finally, a city in Guangdong Province is taken as the research object to verify the performance of the model: the prediction accuracy rate for typhoon "Mujigae" is 0.777 6, and the recall rate is 0.914 0. The results verify the feasibility and effectiveness of the model in predicting power outage space in the case of typhoon disasters. This work is supported by the University-Industry Collaborative Education Program of the Ministry of Education (No. 201902056044).

    参考文献
    相似文献
    引证文献
引用本文

侯 慧,陈 希,李 敏,等.一种Stacking集成结构的台风灾害下停电空间预测方法[J].电力系统保护与控制,2022,50(3):76-84.[HOU Hui, CHEN Xi, LI Min, et al. A space prediction method for power outage in a typhoon disaster based on a Stacking integrated structure[J]. Power System Protection and Control,2022,V50(3):76-84]

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-05-17
  • 最后修改日期:2021-07-14
  • 录用日期:
  • 在线发布日期: 2022-01-30
  • 出版日期:
文章二维码
关闭