高压直流输电开路试验机理分析及解析计算
CSTR:
作者:
作者单位:

(1.华南理工大学电力学院,广东 广州 510641;2.南方电网科学研究院,广东 广州 510080)

作者简介:

张秋实(1993—),男,硕士研究生,研究方向为直流输电系统;E-mail:512900897@qq.com
傅 闯(1973—),男,博士,教授级高级工程师,长期从事大功率电力电子、高压直流输电、电能质量控制等方面的研发和应用工作;E-mail:fuchuang@csg.cn
戴 栋(1976—),男,教授,博士生导师,研究方向为大气压介质阻挡放电的非线性行为。E-mail:ddai@ scut.edu.cn

通讯作者:

中图分类号:

基金项目:

国家自然科学基金项目资助(51777079);国家电网智能电网联合基金项目资助(U1766213);南方电网科技项目资助(ZBKJXM20180104)


Mechanism analysis and analytical calculation of open line test for HVDC transmission
Author:
Affiliation:

(1. School of Electric Power, South China University of Technology, Guangzhou 510641, China;2. Electric Power Research Institute, China Southern Power Grid Co., Ltd, Guangzhou 510080, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    高压直流开路试验(Open Line Test, OLT)是检测换流阀、直流场设备、直流输电线路绝缘是否正常的重要手段。基于电力电子理论和电路理论,采用高压直流工程中换流阀实际运行参数及其触发控制方式,对高压直流开路试验建立可定量计算的等效电路。分别对带和不带直流线路开路试验的试验原理及开路电压建立过程进行解析分析和定量计算,解释了两种工况下开路电压建立的原理与物理本质。采用等效电路定量计算不同工况下开路试验电压,计算结果相比于传统公式误差显著降低。在PSCAD/EMTDC中利用CIGRE高压直流标准测试模型,对计算结果进行了仿真验证。

    Abstract:

    HVDC transmission Open Line Test (OLT) is the normal operation of an important means to detect the converter valves, DC equipment, and DC transmission line insulation. In this paper, the equivalent circuit for quantitative calculation of HVDC OLT is established based on the theory of power electronics and circuit theory and combined with the actual operating parameters and trigger control mode of converter valve in HVDC project. This paper analyzes and calculates the test principle with and without DC line OLT respectively and the process of establishing the open line voltage, and explains the principle and physical essence of establishing open line voltage under the two conditions. On this basis, the equivalent circuit is used to calculate the voltage of OLT under different conditions. The calculation results are more accurate than the traditional formula. The CIGRE simulation model of HVDC system is built by using PSCAD/EMTDC simulation software, and the simulation results are analyzed and verified. This work is supported by National Natural Science Foundation of China (No. 51777079), Smart Grid Joint Fund of State Grid Corporation of China (No. U1766213), and Science and Technology Project of China Southern Power Grid (No. ZBKJXM20180104).

    参考文献
    相似文献
    引证文献
引用本文

张秋实,傅闯,戴栋,等.高压直流输电开路试验机理分析及解析计算[J].电力系统保护与控制,2019,47(5):96-105.[ZHANG Qiushi, FU Chuang, DAI Dong, et al. Mechanism analysis and analytical calculation of open line test for HVDC transmission[J]. Power System Protection and Control,2019,V47(5):96-105]

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2018-03-19
  • 最后修改日期:2018-05-28
  • 录用日期:
  • 在线发布日期: 2019-03-06
  • 出版日期:
文章二维码
关闭