基于综合权重理论和Fuzzy-TOPSIS综合评价的电网静态电压稳定性分析
CSTR:
作者:
作者单位:

(1.新疆大学电气工程学院,新疆 乌鲁木齐 830047;2.国网新疆电力公司电力科学研究院, 新疆 乌鲁木齐 830011;3.国网新疆电力公司乌鲁木齐供电公司, 新疆 乌鲁木齐 830011)

作者简介:

武家辉(1988—),女,博士研究生,研究方向为电力系统稳定与分析;E-mail:wjha29@sina.com
王维庆(1959—),男,通信作者,教授,研究方向为可再生能源并网、电力系统稳定与分析;E-mail:wwq59@sina. com
王海云(1973—),女,教授,研究方向为可再生能源并网。E-mail:327028229@qq.com

通讯作者:

中图分类号:

基金项目:

国家自然科学基金项目资助(51667020);新疆维吾尔自治区重点实验室开放课题资助(2016D03021);博士创新项目资助(XJUBSCX-2015015)


Static voltage stability analysis of power grid based on comprehensive weight evaluation method and fuzzy-TOPSIS
Author:
Affiliation:

(1. School of Electrical Engineering, Xinjiang University, Urumqi 830047, China;2. State Grid Xinjiang Electric Power Research Institute, Urumqi 830011, China;3. State Grid Xinjiang Urumqi Electric Power Company, Urumqi 830011, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    随着电网建设规模的不断扩大与结构日益复杂,电网电压安全稳定问题日益突出。探讨了一种静态电压稳定性指标综合辨识方法。首先,针对以往单一评估指标而导致的评估结果差异性问题,釆用六种静态电压稳定性指标来表征节点电压稳定性。其次,对指标权重系数进行优化,分析指标权重不确定性因素,引入信息熵与层次分析法计算指标综合权重。同时以综合评价值最大和评价值偏离度最小为目标,构建拉格朗日函数优化权重系数;并采用Fuzzy-TOPSIS对计算结果进行排序。最后选用哈密地区部分电网作为案例,分别计算单一指标与所提的综合指标辨识系统稳定与薄弱母线,验证所提方法的有效性与客观性。所得结果可以为系统运行规划,无功补偿等提供依据。

    Abstract:

    The problems of voltage security and stability of power grid are becoming more and more prominent with the expansion of power grid and the complexity of structure construction. As a result, this paper discusses a new method for static voltage stability analysis. Firstly, in order to overcome the sidedness limitation of single-index system in the evaluation of voltage stability, six kinds of voltage stability indexes are combined. Secondly, an index weight optimization method is calculated based on uncertainty factor and a comprehensive evaluation method is used which combines analytic hierarchy process method and entropy method to calculate the weight values. Meanwhile, the aim of the optimization of weights coefficient is to maximize the value of the comprehensive evaluation and minimize the degree of deviation at the same time by using Lagrange conditioned extreme value method, and Fuzzy-TOPSIS is used to rank the results. Finally, taking Hami grid as a study case, both single index and comprehensive index for static voltage stability identification are compared to verify the effectiveness and objectivity of the proposed method. The obtained results can be used to provide basis for system operation scheduling and reactive power compensation. This work is supported by National Natural Science Foundation of China (No. 51667020), Key Laboratory Project of Xinjiang Uygur Autonomous Region (No. 2016D03021) and Doctoral Innovation Project (No. XJUBSCX-2015015).

    参考文献
    相似文献
    引证文献
引用本文

武家辉,王维庆,王海云,等.基于综合权重理论和Fuzzy-TOPSIS综合评价的电网静态电压稳定性分析[J].电力系统保护与控制,2018,46(23):77-85.[WU Jiahui, WANG Weiqing, WANG Haiyun, et al. Static voltage stability analysis of power grid based on comprehensive weight evaluation method and fuzzy-TOPSIS[J]. Power System Protection and Control,2018,V46(23):77-85]