引用本文:刘 健,陈曦子,张志华,等.基于消弧线圈调制信号相关检测的高阻单相接地选线[J].电力系统保护与控制,2023,51(1):63-70.
LIU Jian,CHEN Xizi,ZHANG Zhihua,et al.High resistance single-phase grounding line selection in resonant grounding systemsbased on correlation detection[J].Power System Protection and Control,2023,51(1):63-70
【打印本页】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 7534次   下载 1771 本文二维码信息
码上扫一扫!
分享到: 微信 更多
基于消弧线圈调制信号相关检测的高阻单相接地选线
刘 健1,陈曦子2,张志华1,2,李瑞桂3
(1.国网陕西省电力有限公司电力科学研究院,陕西 西安 710100;2.西安理工大学自动化学院,陕西 西安710048; 3.河北旭辉电气股份有限公司,河北 石家庄 050035)
摘要:
为了提高谐振接地系统单相接地选线的抗过渡电阻能力,提出一种基于相关检测的单相接地选线方法。采用低频方波对消弧线圈补偿电流进行调制,分析故障线路与健全线路调制后的信号特征。将各条线路零序电流分别除以零序电压包络幅值加以调整后进行解调和相关检测。构造了基于互相关函数的单相接地选线判据,讨论了低频调制方波频率的选择对选线效果的影响。结合实例对所提出的方法进行了仿真和实验研究,结果表明所提方法在单相接地选线方面具有非常高的抗过渡电阻能力。
关键词:  配电网  谐振接地系统  单相接地  单相接地选线  相关检测  互相关函数
DOI:10.19783/j.cnki.pspc.220005
分类号:
基金项目:国家自然科学基金重点支持项目资助“城市智能配电网保护与自愈控制关键技术”(U1766208);国家电网公司总部科技项目资助(5226SX22001C)
High resistance single-phase grounding line selection in resonant grounding systemsbased on correlation detection
LIU Jian1, CHEN Xizi2, ZHANG Zhihua1, 2, LI Ruigui3
(1. State Grid Shaanxi Electric Power Research Institute, Xi'an 710100, China; 2. School of Automation, Xi'an University of Technology, Xi'an 710048, China; 3. Hebei Xuhui Electric Co., Ltd., Shijiazhuang 050035, China)
Abstract:
To improve the level of limitation of high resistance single-phase grounding line selection in resonant grounding systems, a single-phase grounding line selection approach based on correlation detection is proposed. The compensation current of an arc suppression coil is modulated with a low-frequency square wave. The signal characteristics of fault and healthy lines after modulation are analyzed. The zero-sequence current of each line divided by the amplitude of zero sequence voltage enveloping is used for demodulation and correlation detection. A single-phase grounding line selection criterion based on a cross-correlation function is constructed and the influence of the selection of low-frequency modulated square wave frequency on line selection effect is analyzed and discussed. Simulation and experiments are carried out, the results of which show that it can accurately select the single-phase grounding line with a large high grounding resistance. This work is supported by the National Natural Science Foundation of China (No. U1766208).
Key words:  distribution networks  resonant grounding systems  single phase grounding (SPG)  single phase grounding line selection  correlation detection  cross correlation function